Pole Mounted Automatic Circuit Recloser
Smart Grid-Ready Reclosing Protection for Rural & Urban Power Systems
Unplanned power outages caused by transient faults, falling branches, or lightning strikes can severely impact reliability. The Pole Mounted Auto Recloser from Wei Shoe Electric is designed to automatically detect, isolate, and restore power in overhead medium voltage distribution networks. Whether you're maintaining long rural feeders or urban grids, this compact, intelligent solution minimizes downtime and improves grid stability—without requiring on-site intervention.
⚙️ What Is a Mounted Auto Recloser?
An auto recloser is a switchgear device that automatically opens and recloses a line when a fault is detected. Installed on distribution poles (typically at 11kV–33kV), it is essential in modern power grids for:
Reducing service interruptions from temporary faults
Preventing cascading outages
Allowing remote monitoring and operation via SCADA
Wei Shoe’s unit integrates a vacuum interrupter, an intelligent controller, voltage/current sensors, and a communication module into a weatherproof body.
✅ Key Benefits
Voltage range: 11kV / 15kV / 24kV / 33kV
Rated current: 630A / 800A
Breaking capacity: 16kA–25kA
Insulation: Solid dielectric (no SF6 gas)
Reclosing cycles: Programmable (1–4 times)
Control modes: Local, Remote (via SCADA), Auto
Standard compliance: IEC 62271-111, IEEE C37.60
📈 Real-World Application: Uganda Rural Grid Modernization (2023)
In 2023, Wei Shoe Electric supplied 40 sets of 15kV pole-mounted reclosers to the Uganda Electricity Distribution Company Ltd (UEDCL). These units were installed on 60–90km rural feeders to:
Reduce manual fault patrol distance
Improve SAIDI/SAIFI indices
Enable fault isolation via GSM remote control
After 12 months, the recorded fault clearance time dropped by 78%, with zero SF6 gas leakage reported.
🔍 Ideal For These Applications
Rural medium-voltage feeders with long spans
Overhead lines with vegetation risks
Mini-substations and pole transformer protection
Microgrid sectionalizing and renewable energy tie-ins
Smart grid SCADA integration projects
📊 Technical Parameters
| Parameter | Specification |
|---|---|
| Rated voltage | 11kV / 15kV / 24kV / 33kV |
| Rated frequency | 50/60 Hz |
| Rated current | 630A / 800A |
| Short-circuit breaking capacity | 16–25 kA |
| Rated insulation level | 95 kV / 170 kV impulse |
| Reclosing operations | Configurable 1–4 attempts |
| Control mode | Auto / Manual / Remote |
| Communication | GSM / GPRS / RS-485 / IEC 61850 |
| Operating mechanism | Magnetic actuator |
| Weatherproof rating | IP67 |
❓ Frequently Asked Questions
• What is the difference between a recloser and a circuit breaker?
A recloser automatically recloses after a fault; circuit breakers generally trip and remain open until manually reset.
• Does it require a SCADA system to operate?
No, it can operate independently in automatic mode or be connected to SCADA via GSM, GPRS, or IEC 61850 protocols.
• Can it be used in remote areas without internet?
Yes, reclosers support GSM-based control and also offer local manual operation.
• Is there any maintenance needed?
Minimal. No SF6, no oil. Annual inspection of contacts and control module is sufficient.
• What standard tests has it passed?
All units are type-tested according to IEC 62271-111 and IEEE C37.60.
👷 About the Engineer
My name is Thor, an electrical engineer at Wei Shoe Electric, specializing in fault protection devices for over 12 years. I’ve worked with utilities and contractors in Southeast Asia, Africa, and South America on recloser deployment, smart grid retrofits, and custom MV switchgear. I’d be happy to assist with technical support, drawings, or BOQ consultations.