27kV auto recloser Vacuum Recloser with Control
⚡ Boost Grid Reliability with 27kV Pole-Mounted Auto Recloser
The 27kV Auto Vacuum Recloser is a smart pole-mounted switching device engineered for automatic fault isolation and self-reclosing in medium-voltage distribution networks. Ideal for 27kV overhead lines, this recloser minimizes service interruptions caused by temporary faults, such as lightning or tree contact.
Manufactured under IEC 62271-111 / IEEE C37.60, the recloser integrates vacuum interrupters, a high-speed control unit, and wireless communication options for SCADA systems. It’s widely used in rural electrification, smart grids, and renewable energy systems.
🔧 Technical Specifications
| Parameter | Value |
|---|---|
| Rated Voltage | 27kV |
| Rated Current | 630A / 800A |
| Short-Circuit Breaking | 12.5kA / 16kA |
| Rated Frequency | 50Hz / 60Hz |
| Rated Insulation Level | 60kV/125kV BIL |
| No. of Reclose Attempts | Configurable (1~4 times) |
| Control Unit Type | Integrated or Remote |
| Communication Protocol | IEC 60870-5-101/104, Modbus, DNP3 |
| Operation Mechanism | Motor spring-charged |
| Ambient Temperature | -40°C to +55°C |
| Protection Grades | IP65 (Main body), IP67 (Controller) |

🌍 Why Utilities Choose This Recloser
Fast Automatic Fault Isolation
Detects and isolates transient faults, improving system uptime and reducing truck rolls.Vacuum Interruption + Polymer Housing
Arc-quenching vacuum chambers are combined with weather-resistant, insulated composite material.Integrated Smart Controller
Supports logic reclosing, remote monitoring, event logs, and fault diagnostics.Wide Climate Adaptability
Built for harsh weather, from Canadian winters to Southeast Asian humidity.SCADA-Ready
Seamlessly integrates with utility supervisory control systems.
🚀 Application Scenarios
Rural Electrification Grids
Prevents prolonged blackouts in long radial lines.Solar/Wind Collector Networks
Protects feeder lines and enhances grid resilience under variable load.Industrial Parks & Data Centers
Enables rapid fault clearing and minimizes downtime.Storm-Prone Utility Regions
Automatically restores service after lightning-induced trips.

🌟 Verified Customer Feedback
🔹 Claire D. – Asset Manager, Duke Energy (USA)
"Recloser performance is outstanding during storm seasons. Saved us hours of outage each month."
🔹 Jan Eriksson – Lead Engineer, Vattenfall (Sweden)
Operates flawlessly even under snow and ice buildup. Remote diagnostics are accurate."
🔹 Rafael M. – Grid Planner, Energisa Group (Brazil)
"Installation was smooth, and integration with SCADA took under 2 hours. Highly recommended."
🔹 Timothy O. – Procurement Officer, Kenya Power
"We deployed 40+ units across rural grids—no major service calls since deployment."
🔹 Lucy W. – Substation Supervisor, Ausgrid (Australia)
"Helps us meet SAIDI/SAIFI targets by reducing manual switching delays."
❓ FAQ – 27kV Auto Vacuum Recloser
• How many times can it reclose after a fault?
Typically set to 3 or 4 times, programmable through the control panel.
• Can it detect permanent vs. transient faults?
Yes. Smart controller differentiates fault types and locks out on persistent failures.
• Is communication encrypted?
Supported protocols use industry-standard security layers.
• Is the device maintenance-free?
Designed for minimal intervention. Yearly inspection is sufficient in most settings.
• Does it support GPS time-sync?
Yes, GPS-based time synchronization is optional for event tracking accuracy.